K3163i Intelligent Protection Relay Test Set

All-in-One design, weight < 17.5kg;
High Power & Accuracy with 6x35A & 4x310V analog outputs;
Complying IEC61850 Sampling Value & GOOSE;
The ever-expanding test library templates;
Optional advance functions like energy meter and transducer calibration etc.

Description:

Basic Functions
● Universal Relay Test Applications
● 10 Channels (6x35A & 4x310V) outputs, Each output channels are independent and simultaneous control of magnitude, Phase angle and frequency values, able to inject DC, AC sine wave and up to 60x harmonics.
● 13 Low-level channels outputs up to 8Vac/10Vdc max.
● 100/1000Mbit Fiber port for SMV and GOOSE simulations
● Variable battery simulator, DC 0-350V, 140Watts max.
● Transient play back up to 3KHz
● Fully function KRT software testing modules
● Graphical test modules and templates for testing of various relays
● Quick relay testing facility in Manual mode
● Shot/Search/Check, Point & Click testing
● RIO/XRIO import & export facility
● Switch on to fault test(SOTF)
● Power system model for dynamic testing
● Online Vector display
● Automatic test results assume
● Automatic test report creation
● Inbuilt GPS and IRIG-B sync end-to-end testing
● Anti-clipping detect, Wrong wiring connect alarm and self-protect, overload and overheat protection
● 3-Years guarantee of free repair and life-long maintenance
● Lightweight, <18Kg
● Free software upgrade

Advance Feature
● Complied IEC61850-9-1, IEC61850-9-2, IEC60044-7/8, etc
● Transducer calibration (0.02 class)
● Energy meter calibration (Mechanical & Electronic meters)

Type of relays can be tested:
ItemsANSI® No.
IEC61850 numerical IEDs relay & merge unit 
Distance protection relay21
Synchronising or synchronism-check relays25
Undervoltage relays27
Directional Power relays32
Undercurrent or underpower relays37
Negative sequence overcurrent relays46
Overcurrent/ground fault relays50
Inverse time overcurrent/ground fault relays51
Power factor relays55
Overvoltage relays59
Voltage or current balance relays60
Directional overcurrent relays67
Directional ground fault relays67N
DC overcurrent relays76
Phase-angle measuring or out-of-step protection relays78
Automatic reclosing devices79
Frequency relays81
Motor overload protection relays86
Differential protection relays87
Directional voltage relays91
Voltage and power directional relays92
Tripping relays94
Voltage regulating relays 
Overimpedance relays, Z> 
Underimpedance relays, Z 
Time-delay relays 
K3163i Intelligent Protection Relay Test Set
Specification Details
Voltage Outputs
  • Output Range & Power: 4×310 V ac (L-N) 124 VA max each
  • 3×350 V dc (L-N) 140 W max each
  • Accuracy: <0.02%Rd+0.005Rg Typ. / <0.05%Rd+0.01Rg Guar.
  • ±10mV @ <5V dc / ±0.5% @ ≥5V dc
  • Voltage Range: Range I: 30V, Range II: 310V
  • Automatic Range
  • DC Offset: <20mV Typ./ <100mV Guar
  • Resolution: 1mV
  • Distortion: <0.015%Typ. / <0.05% Guar.
Current Outputs
  • Output Range & Power: 6×35A ac (L-N) 480 VA max each
  • 3×70A ac (2L-N) 850 VA max each
  • 1×100A ac (6L-N) 1200 VA max
  • 3×20A dc (L-N) 300W max each
  • Accuracy: <0.03%Rd+0.02Rg Typ. / <0.1%Rd+0.05Rg Guar.
  • ±5mA @ <1A dc / ±0.5% @ ≥1A dc
  • Current Range: Range I: 3A, Range II: 35A
  • Automatic Range
  • DC Offset: <3mA Typ./ <10mA Guar
  • Resolution: 1mA
  • Distortion: <0.025%Typ. / <0.07% Guar.
Low-Level Output
  • Quantity: 13 Channels, 16 pin combination female socket
  • Voltage Outputs Range: AC 0~8V, DC 0~10V
  • Current Outputs Range: Nominal 2mA, 10mA max transient
  • Output Power: ≥0.5VA
  • Accuracy (0.01~0.8 Vrms): <0.05% Typ. / <0.1% Guar.
  • (0.8~8 Vrms): <0.02% Typ. / <0.05% Guar.
  • Resolution: 0.25mV
  • Distortion (THD%): <0.05% Typ. / <0.1% Guar.
  • Frequency Range: 0~3000KHz
  • DC Offset: <0.15mV Typ. / <1.5mV Guar.
Frequency & Phase Angle
  • Frequency Range: DC~1KHz, 3KHz transient
  • Frequency Accuracy: ±0.5ppm
  • Frequency Resolution: 0.001 Hz
  • Phase Range: -360°~360°
  • Phase Accuracy: <0.02° Typ. / <0.1° Guar. 50/60Hz
  • Phase Resolution: 0.001°
Aux. DC Voltage Source (Battery simulator) Range: 0~350V @ 140W max, Accuracy: 0.5%Rg Guar.
Binary Input
  • Quantity: 8 pairs
  • Type: wet/dry, measurement
  • Threshold: 10~600Vdc or potential free, Programmable
  • Time resolution: 10us
  • Sampling Rate: 10KHz
  • Debounce time: 0~25ms (Software Controlled)
  • Time range: Infinite
  • Time errors: ±1ms @ ≤1s, ±0.1% @ >1s
  • Galvanic isolation: 4 isolated with each 2 pairs
Binary Output (Relay Type)
  • Quantity: 4 pairs
  • Type: Potential free relay contacts, software controlled
  • Break Capacity AC: Vmax: 400Vac / Imax:8A / Pmax:2500VA
  • Break Capacity DC: Vmax: 300Vdc / Imax:5A / Pmax:150W
Binary Output (Semiconductor Type)
  • Quantity: 4 pairs
  • Type: Open-collector, Combination type female
  • Break Capacity DC: 5~15Vdc / 5mA, 10mA max
  • AC not permitted
  • Response time: 100us
Synchronization
  • Synchronization Mode: GPS, SMA type antenna connector
  • IRIG-B (Optical fiber, FT3 type)
Power supply & Environment
  • Nominal Input Voltage: 100~240Vac
  • Permissible Input Voltage: 85~260Vac, 125~350VDC
  • Nominal Frequency: 50/60Hz
  • Permissible Frequency: 45Hz~65Hz
  • Power Consumption: 1500 VA max
  • Connection Type: Standard AC socket 60320
  • Operating Temperature: -10℃~55℃
  • Storage Temperature: -20℃~70℃
  • Humidity: <95%RH, non-condensing
PC Connection RJ45 Ethernet, 10/100M
Grounding Terminal 4mm banana socket
Weight 17.5 Kg
Dimensions (W x D x H) 468×375×164(mm)
Optional Modules
  • IEC61850 functions:
    • Fully complying IEC61850 Sampling value and GOOSE; (IEC61850-9-1, IEC61850-9-2/(LE), IEC60044-7/8)
    • Able to simultaneously output sampling value and analog signals, or subscriber and publish GOOSE message and relay contact binary I/O function
    • Up to 36 sampling value channels can be mapped
  • IEC61850 Fiber & GOOSE Ethernet Ports (Optional Function):
    • Fiber Ports: 2 x 100Base-FX Full Duplex, LC type
    • Optional to 10/100Mbit, Ethernet RJ45 type
    • Fiber Type: 62.5/125um (Multiple optical fiber, Orange Red)
    • Wavelength: 1310nm
    • Transmit Distance: >1Km
    • Indicator: Spd Green(light): Valid connection, Link/Act Yellow(Blinking): Data exchanging
  • Transducer Calibration Function:
    • DC Measurement Input:
      • Voltage Input Range: 0~±10V dc
      • Max Input: ±11V dc
      • Accuracy: <0.2% rg Typ. <0.5% rg Guar.
      • Input Impedance: 1M ohm
    • Current Input Range: 0~±1mA / 1~±20mA, auto range
    • Max Input: 600mA
    • Accuracy: <0.2% rg Typ. <0.5% rg Guar.
    • Input Impedance: 15 ohm
  • Energy Meter Calibration Function:
    • Sensor Usage: Mechanical meters / Electronic meters
    • Sensor Output: High lever:>4.5V, Low level:<0.2V
    • Pulse Input: 1 pulse input port, 5Vdc high level valid only
    • Pulse Range: 500KHz pulse input Max.
    • Pulse Output: 1 Transistor output, Open-collector, 5Vdc/5mA
Ordering instructions
  • K3166i: 6×35A @ 450VA max, 3×70A @ 850VA max, 7×310V @ 90VA max
  • IEC61850 SV, IEC61850 GOOSE, Energy meter cal., Transducer cal.
  • K3163i: 6×35A @ 450VA max, 3×70A @ 850VA max, 4×310V @ 124VA max
  • K3130i: 3×35A @ 450VA max, 4×310V @ 124VA max