PMC96 series three-phase electric monitoring meter

PMC96 series three-phase electric monitoring meter adopts Segment type LCD screen、beautiful and grand,high contrast; With high-speed processor as the core, measurement of electric parameters using 22 AD, electric energy metering, wide dynamic range, high accuracy. Can optional configure various binary、relay、RS-485 communication module, can easily fulfill the integration of various intelligent distribution system.

Description:

Features:
● Adopts 22 AD for achieve electric parameter measurement, electric energy metering, wide dynamic range, high accuracy;
● Electric parameter over-limit alarm monitoring, alarm output relay association;
● Support 2-channel DI/DO,1 channel electric energy pulse output;
● Support MODBUS-RTS standard protocol, RS485 communication.

Series Model:
● PMC96S-I Three-phase digital current meter
● PMC96S-U Three-phase digital voltage meter
● PMC96S-P Three-phase digital power meter
● PMC96S-C Three-phase digital power factor meter
● PMC96S-Z Three-phase electric monitoring meter
● PMC96SL-I Three-phase LCD screen current meter
● PMC96SL-U Three-phase LCD screen voltage meter
● PMC96SL-P Three-phase LCD screen power meter
● PMC96SL-C Three-phase LCD screen power factor meter
● PMC96SL-Z Three-phase electric monitoring meter

Applications;
● Industrial distribution automation system
● Power plant auxiliary system
● Substation automation system
● Energy management system
● Intelligent mansion electrical engineering
● Switch gear of high & low voltage

PMC96 Series Three-Phase Electric Monitoring Meter
Specification Details
Product Models
  • PMC96L-Z
  • PMC96-Z
  • PMC96L-C
  • PMC96-C
  • PMC96L-P
  • PMC96-P
  • PMC96L-U
  • PMC96-U
  • PMC96L-I
  • PMC96-I
Instantaneous Real Virtual Value
  • Current Single phase & neutral line
  • Voltage Line/line & Phase/line
  • Frequency
  • Active power 3-phase & Single phase
  • Reactive power 3-phase & Single phase
  • Power factor 3-phase & Single phase
Energy
  • Active energy 1 channel pulse output
  • Reactive energy
Communication
  • MODBUS-RTU protocol
  • Optional 1 channel RS485
Display LCD or Digital display
Other Support program online upgrade
Optional Function
  • 2-channel DI
  • 2-channel DO
  • 2-channel limits alarm
Electrical Characteristics
  • Measurement type: Three-phase three-wire AC system, Three-phase four-wire AC system
  • Sampling rate: 64 times per cycle
  • Data refresh rate: 1S
Measurement Accuracy
  • Current: 0.5%
  • Voltage: 0.5%
  • Power: 0.5%
  • Frequency: 0.05Hz
  • Active Energy: 1.0%
  • Reactive Energy: 2.0%
  • AO: 1%
Input Voltage Characteristics
  • Measuring voltage: 3 X 220/380V (connected directly), 3 X 57.7/100V (connected by CT)
  • Allowed load: 1.2 times / continuous
  • Input impedance: 1.8MΩ
Input Current Characteristics
  • Measuring current: 5A or 1A (connected by CT)
  • Allowed load: 1.2 times / continuous
  • Input impedance: <0.1Ω
Binary Input
  • Working voltage: Passive dry contact (built-in +15VDC power supply)
  • Input impedance: 5KΩ
  • Isolation voltage: 2KV
Relay Output
  • Node type: Mechanical shock
  • Node capacity: 220 VAC/5A, 30 VDC/5A
Working Power Supply
  • AC: 85~265 VAC/45-65Hz
  • DC: 100~300 VDC
  • Power dissipation: < 3W
Mechanical Properties
  • Weight: 0.5kg
  • IP protection grade: Panel IP52, body IP30
  • Size: 96 X 96 X 102mm
Operating Temperature -10~55℃
Storage Temperature -20~70℃
Relative Humidity 5% - 90%RH, No condensation
EMC
  • Electrostatic discharge interference: IEC 61000-4-2, Level 4
  • Group of anti-fast transient pulse: IEC 61000-4-4, Level 4
  • Anti-impact: IEC 61000-4-5, Level 3
  • Anti-frequency magnetic field: IEC 61000-4-8, Level 3
Electrical Insulation Performance
  • Insulation resistance: GB/T13729, >50MΩ
  • Frequency withstand voltage: GB/T13729, AC 2KV 50Hz /1min
  • Impulse voltage: GB/T13729, 5KV, 1.2/50us
Ordering Instruction
  • Model Specification: PMC96A-B-C-D-E-F
  • A Model specification:
  • PMC96L: LCD Display
  • PMC96: Digital Display
  • B Means type:
  • I: 3-Phase current meter
  • U: 3-Phase voltage meter
  • P: 3-Phase power meter
  • C: 3-Phase power factor meter
  • Z: 3-Phase power monitoring meter
  • C Means Rated measurement voltage, current:
  • 1: 57.7/100V, 5A
  • 2: 57.7/100V, 1A
  • 3: 220/380V, 5A
  • 4: 220/380V, 1A
  • D System frequency:
  • 1: 50Hz
  • 2: 60Hz
  • E Working power supply:
  • 1: 100~300VDC, 85~265VAC/45~65Hz
  • F Optional function:
  • S: ### HTML (Continued) ```html 2-Channel Binary Input
  • R: 2-Channel Relay Output
  • C: 1 Channel RS485

Optimize Your Industrial Efficiency Today

Unlock unparalleled productivity and efficiency with Third Eye Automation’s cutting-edge solutions. Contact us to learn more.

"*" indicates required fields

Name*