KF85P Universal Relay Test Set

The world’s lightest & high power universal relay test set
●  6x35A@425VA max & 6x310V@105VA max analog outputs
●  10kg weight, easy carry on flight journey
●  Low-level signals output, energy meter testing, transducer calibration and IEC61850 testing capability for optional.

Description:

Basic Functions
The KF85P is a multipurpose, light-weight, field portable test set, it capable of testing a wide variety of electro-mechanical, solid state and microprocessor based protective relays, motor overload relays, IEC61850 testing, and similar protective devices.
●  12 Analog Channels outputs, 6x35A & 6x310V, Each output channels are independent and simultaneous control of magnitude, Phase angle and frequency values, able to inject DC, AC sine wave and up to 60x harmonics.
●  Lightweight, <10Kg, easy carry on flight journey
●  Variable battery simulator, 24~350Vdc, 70Watts max output. Easily supply power for most protection devices.
●  Fully function KRT software for test management, graphical test modules, template organized, Xrio/Rio import/export, testing result review, auto result assessment and report generate, etc.
●  Transient play back up to 3KHz
●  8×100/1000Mbit Fiber port for IEC61850 SMV and GOOSE simulations
●  Inbuilt GPS and IRIG-B synchronized end-to-end testing capability
●  10 binary input, dry contacts or 0-300V potential contacts capability; 4 fast binary outputs isolated each and with <1ms response time.
●  Anti-clipping detect, Wrong wiring connect alarm and self-protect, overload and overheat protection
●  AC 85~265 / DC 127-350 power supply, World wide range power supply compatibility
●  3-Year free warranty and life-long maintenance
●  Free software upgrade

Advance Feature
●  Complied IEC61850 edition 1.0 & 2.0 standard
●  Transducer calibration
●  Energy meter calibration (Mechanical & Electronic meters)
●  10 Low-level analog outputs (8 Voltages + 2 Currents) up to 8V/20mA max.

KFA300 Mini Handheld Protection Relay Tester
Specification Details
AC Current Source Amplitude & Power: 6×35A @ 424VA max each; 3×70A @ 670VA max each
Accuracy: <0.015%Rd+0.005%Rg Typ., <0.04%Rd+0.01%Rg Guar.
Range: Range I: 3A, Range II: 35A
Automatic Range
DC Offset: <3mA Typ./ <10mA Guar
Resolution: 1mA
Distortion: <0.025%Typ. / <0.07% Guar.
Ascends/Descent response: <100us
DC Current Source Amplitude & Power: 3×20A @ 400W max
Accuracy: ±5mA @ <1A, ±0.2% @ ≥1A
Ascends/Descent response: <100us
AC Voltage Source Amplitude & Power: 6×310V @ 105VA max each
Accuracy: <0.015%Rd+0.005Rg Typ., <0.04%Rd+0.01Rg Guar.
Range: Range I: 30V, Range II: 310V
Automatic Range
DC Offset: <10mV Typ./ <60mV Guar
Resolution: 1mV
Distortion: <0.015%Typ. / <0.05% Guar.
Ascends/Descent response: <100us
DC Voltage Source Amplitude & Power: 6×350V @ 100W max; 3×700V @ 150W max
Accuracy: ±10mV @ <5V, ±0.2% @ ≥5V
Ascends/Descent response: <100us
Frequency & Phase Angle Frequency Range: DC ~ 1000Hz, 3000Hz transient
Frequency Accuracy: ±0.5ppm
Frequency Resolution: 0.001Hz
Phase Range: -360°~360°
Phase Accuracy: <0.02° Typ. / <0.1° Guar. 50/60Hz
Phase Resolution: 0.001°
Auxiliary DC Supply (Battery Simulator) Range: 8 ~ 60Vdc (Max Load Current 1.16A) Accuracy<2%, 60 ~ 120Vdc (Max Load Current 0.58A) Accuracy<1%, 120 ~ 350Vdc (Max Load Current 0.2A) Accuracy<0.5%
Resolution: 10mV
Protection: Short-circuit protection, Overload Protection: Yes, Isolation: Isolated from other terminals
Binary Input Electrical isolation: 10 pairs of electrical isolated each, Input impedance: 5 kΩ…13kΩ(Empty contact), Input feature: 0 V~300Vdc Or dry contact
Sampling Rate: 10kHz, Time resolution: 10us, Time measurement range: infinity, Time accuracy: ±1ms @ <1s, ±0.1% @ ≥1s, Debounce time: 0~25ms (Software controlled)
Binary Output Quantity: 4 pairs, Type: Fast speed transistor, programmable software control, AC break capacity: Vmax:250V(AC)/ Imax:0.5A, DC break capacity: Vmax:250V(DC)/ Imax:0.5A, Electrical isolation: All pairs isolated
Time Synchronization Satellite synchronization: 1 × SMA,Use for GPS antenna interface, Support: GPS and Beidou Satellite, Fiber IRIG-B: 2 × ST,1 for transmission, 1 for receiving, Electric IRIG-B: 1 × 6Pin 5.08mm phoenix terminal, 1 for transmission, 1 for receiving, External trigger synchronization: 1 × 4Pin 5.08mm phoenix terminal, external trigger input + external trigger output
Sync error: <10us
Communication Interface Ethernet: 2 × RJ45 ,10/100M, WIFI: Inbuilt WIFI DHCP service, Serial port: 1 × RS232, USB: 2 × USB2
Weight & Size Size: 390mm×256mm×140mm, Weight: 10kg
Power Supply Nominal voltage: 220V/110V (AC), Allowable voltage: 85 - 265 VAC ;127V~350V(DC), Nominal Frequency: 50Hz, Allowable Frequency: 47-63Hz, Current: 10A max, Power Consumption: 1200VA max, Connection Type: Standard AC socket 60320
Working Environment Operating temperature: -10~+55℃, Relative humidity: 5~95%,Non-condensation, Storage temperature: -20℃ ~ +70℃, Atmospheric pressure: 80kPa~110 kPa(alt### HTML (Continued) ```html ude 2000m or lower)
Optional Modules IEC61850 functions: Fully complying IEC61850 Sampling value and GOOSE; (IEC61850-9-1, IEC61850-9-2/(LE), IEC60044-7/8), Able to simultaneously output sampling value and analog signals, or subscriber and publish GOOSE message and relay contact binary I/O function, Up to 36 sampling value channels can be mapped
Fiber port (LC type): Type: 100Base-FX (100Mbit,Fiber, full duplex), Port Number: 8 Pairs, Cable model: 62.5/125μm(Multiple-mode fiber, orange), Wave length: 1310nm, Transmission distance: > 1Km, Status indication: SPD Green (lights): active connection, Link\AcT Yellow (blinking): data exchange
Low-Level Channels Signal Output Function Output channels: 10 channels, 8 Voltage outputs + 2 Current outputs, Output port type: Phoenix terminal, Output range: 8x0~8Vrms; 2x0~20mA, Accuracy (0.01~0.8 Vrms/0~2mA):<0.05% Typ. / <0.1% Guar., (0.8~8 Vrms/2~20mA): <0.02% Typ. / <0.05% Guar., Resolution: 250µV, Harmonic(THD%): < 0.05% Typ. / <0.1% Guar., Frequency range: DC~1.0kHz, transient 3KHz, Frequency accuracy: 0.002%(Normal frequency), Frequency resolution: 0.001Hz, Phase range: 0~359.9°, Phase accuracy: <0.02°,50/60Hz, Phase resolution: ±0.001°
Transducer Calibration Function DC Measurement Input: Voltage Input Range: 0~±10V dc, Max Input: ±11V dc, Accuracy: <0.05% rg Typ. <0.02% rg Guar., Input Impedance: 1M ohm, Current Input Range: 0~±1mA / 1~±20mA, auto range, Max Input: 600mA, Accuracy: <0.05% rg Typ. <0.02% rg Guar., Input Impedance: 15 ohm
Energy Meter Calibration Function Sensor Usage: Mechanical meters / Electronic meters, Sensor Output: High lever:>4.5V, Low level:<0.2V, Pulse Input: 1 pulse input port, 5Vdc high level valid only, Pulse Range: 500KHz pulse input Max., Pulse Output: 1 Transistor output, Open-collector, 5Vdc/5mA

Optimize Your Industrial Efficiency Today

Unlock unparalleled productivity and efficiency with Third Eye Automation’s cutting-edge solutions. Contact us to learn more.

"*" indicates required fields

Name*